SURFACE PREPARATION
Surface preparation must be done in accordance with the State Building Standard of Ukraine DBN V.2.6-22-2001. The base must be:
- clean (remove dirt, flows and remains from previous operations that reduce adhesion);
- strong (remove loose areas and treat with the primer TM MASTER);
- align uneven surfaces of the base of more than 20 mm with a mix for repairing floors ТМ MASTER (24 hours before the start of work);
- previously treat surfaces with high absorptive capacity with the primer TM MASTER.
When applying tiles to unstable bases, bases with load bearing property, or indefinite bases (e.g., loose, or difficult to clean) check the adhesion, namely: apply tile and check adhesion with the base after 48 hours.
INSTRUCTIONS FOR USE
Operations using mix TM MASTER. PLITOPOL should be carried out at an air temperature of +50С to +300С; at the same time, protect the facing made from direct sunlight, wind and rain.
Add water to the dry mix ТМ MASTER. PLITOPOL as per the technical data, then mix it (for efficient mixing, use drill with screw socket). Leave closed mix for 5 minutes, then stir again. Use the mix ТМ MASTER. PLITOPOL for 120 minutes (in case of mobility reduction, periodically stir the mix at high temperature in summer).
The adhesive mix TM MASTER. PLITOPOL is applied to the prepared base using a smooth metal float, and then evenly distributed and profiled by a notched float. Do not apply tiles with closed joints.
If the floor faced is outside the building, additionally put the mix on the back surface of tiles. Apply on the base the amount of mix so that to after pressing the tile to the surface the entire space under it was filled, keeping the intended thickness.
The time for applying tiles on the mix applied (open time) varies depending on the base and the environment. To be sure that you can still apply tiles on the applied mix, touch the previously applied layer of the mix. If the adhesive mix remains on the fingers, you can apply tiles. If the fingers are clean, it is necessary to remove the old layer of the adhesive and apply a new one. Clean the excess of adhesive that appears at the joints when pressing tiles timely.
Conduct grouting between tiles no earlier than 48 hours after applying tiles on the surface. We recommend using grout ТМ iMASTER.
NOTE TO A BUYER
- The base strength must be not less than the strength of the mix;
- Failure to follow the instructions for use mentioned on the package may adversely affect the aesthetic and performance properties;
- Products are not subject to mandatory certification;
- The mix is safe for human health in the production, transportation, storage, application and during the operation subject to following the requirements of this standard to production safety and health;
- Keep away from children;
- Date of manufacture, shelf life and batch number are mentioned on the package;
- Use only for the intended purpose.
- The manufacturer is not responsible for the use of the material for the purpose and under conditions not covered by this instruction.
- This instruction is a recommendation and does not substitute the professional training of the contractor.
Dry building mix ТМ MASTER C.1.ЗК2 DSTU B V.2.7-126:2011
|
Ingredients
|
Cement mix, modified with polymeric additives
|
|
Size of aggregate
|
maximum 0.8 mm
|
|
Time the mix is suitable for use
|
120 minutes
|
|
Open time
|
10-25 minutes
|
|
Strength of adhesion to base
|
0.8 MPa
|
|
Recommended amount of water for preparing the mix
|
0.19 - 0.2 L / 1 kg
|
|
Application temperature
|
+50С to +300С
|
|
Operation temperature
|
-400С to +700С
|
|
Compressive strength
|
min 3 MPa
|
|
Mix consumption
|
1.9 kg / m2 / 1 mm and above
|
All of these recommendations are efficient at +20С and relative humidity of 60%.
SAFETY RULES
Dry building mixture contains cement, which causes alkaline reaction in hydration. When using the mix, use the personal protective equipment (respirator and rubber gloves). When working, protect the skin and eyes. In case of a mixture contact with eyes, rinse them immediately with plenty of water and seek medical advice.
Expiration date: 12 months from date of manufacturing in original packaging in a dry place. The date of manufacture is indicated on the bag.
Storage conditions: Store in the original intact packaging, on pallets, in dry premises at temperatures below 400С and humidity of 75%.
Warranty period: The manufacturer guarantees compliance of the quality with the requirements of this standard for the period specified on the package, provided the requirements of transport and storage are followed.