Questions and answers for planners - treatment plants Biotal | b
Skip to main content [#main-content] Home ABOUT US Manufacturing Patents Certificates Awards Warranty obligations Our customers Reviews BIOTAL TECHNOLOGY Author of the technology Why BIOTAL? Advantages of BIOTAL plants A comprehensive treatment for petrol stations PRODUCTS Monoblock plants Standard - (Т) Standard-BIO (ТВ) Comfort (ТSD) Exclusive (ТBSD) Reinforcement, without ferroconcrete pit Block-module plants Block-module overground plants Block-module underground plants Ferroconcrete construction plants Single modular ferroconcrete plants Two-module ferroconcrete construction plants Grease removers Photogallery Box-recuperator Grids for the coarse dirt detention PLANNING Information for planning Secondary use Treated wastewater discharge Exploitation Power supply and Control FAQ Questions and answers for clients Questions and answers for planners CONTACTS UKRBIOTAL contacts Representatives contacts QUALITY DOWNLOAD NEWS en ru ua facebook vk youtube Deep biological wastewater treatment plants. +38 (0362) 26-28-97 +38 (0362) 26-64-17 General office, Marketing manager Choose the plant We will help you to make the right choice The calculation of the wastewater flow at rates to one equivalent user Consumption, l/person Equivalent users amount, person. Consumption, m3/day Residential buildings 300 Number of equivalent users, l * Consumption, m3/day Hotels, guest houses, holiday homes, motels, childrens camps, boarding schools 230 Number of equivalent users, l * Consumption, m3/day Administrative buildings, offices, educational institutions, industrial goods shops, clinics 25 Number of equivalent users, l * Consumption, m3/day Swimming pools, gyms, stadiums 100 Number of equivalent users, l * Consumption, m3/day Hospitals 240 Number of equivalent users, l * Consumption, m3/day Your e-mail e-mail * In total In total * Home Questions and answers for planners We offer Monobloсk plants 1,5-10 m3/day Block-module plants 8-300 m3/day Ferroconcrete execution plants 10-2400 m3/day Grease removers 1-5 l/s Questions and answers for planners What should be the distance from the monoblock plant to the compressor? If possible, the distance should be minimized, to avoid loss of air pressure. If the electrical equipment will be placed in a residential building, it is necessary to consider that the monoblock plant BIOTAL sanitary protection zone is 5 m. In the case, if nearby the plant there is no existing building for placing the compressor, you can either build special light construction of the sandwich panels, or purchase box-recuperator. When should pre-treatment of waste water be provided? In most cases, domestic waste water does not require pre-treatment. However, if you are planning to clean waste water from the cafes, restaurants, hotels, etc., pre-treatment of wastewater from oil is needed, grease separator is installed (SNIP 2.04.01-85, p.15.2, 15.3). Grease separators must be provided before mixing production (from sinks) wastewater with other domestic waste waters. How to choose capacity of plant for petrol stations? From experience with similar plants we recommend taking into consideration not only petrol stations employees, but also customers, that also will use sanitary appliances. Thus, we can not provide for petrol stations plants with capacity less than 3 m3/day. At what distance from the gas supply pipe can plant BIOTAL be placed? Placement of the plant regarding existing underground utilities is regulated by building regulations, namely, DBN 360-92 *. How to choose the correct pumps for treated water pumping ? For the correct pumping of treated water pump should be set according to the following conditions: 1) The minimum capacity of the pump should be - Capacity plant/number of program cycles (10) Example: BIOTAL-50 (50 m³/day) 50/10 = 5 m³/h When choosing a pump is necessary to consider raising the height of the water and the distance to the water intake. 2) Use a check valve so that part of pumped out water is not returning back into the pin tank. 3) The pump must have a float, which will automatically switch off the pump at the lowest level. 4) recommend using duplication of pumps pump the treated water, as the failure of the pump will lead to flooding plant or to outflow through the emergency hole. How to choose the correct pumps for treated water pumping? To determine this, it is necessary to carry out geological surveys in the area, which is planned to place the drain. Depending on the absorption coefficient of the soil (which is determined by its type, the sandy soil is able to filter more water per day, rather than, for example, clay loam) is calculated as the area required for drainage. Nevertheless, it should be borne in mind that if the water use of the object exceeds 10 - 16 m3, should consider another method of diversion of water as the soil is not able to filter out such quantities of water. In this case, you might consider dumping into the water - because water quality at the output of the plant BIOTAL allow it in full. What should I do if the flow of the plant BIOTAL gets to the level of soil freezing? If you can not pump water to the plant BIOTAL pressure-free, SPS should be provided. For monoblock plants - this is a ferroconcrete well, in which a pump is situated. As soon as received effluent is pumped to the plant of treatment technology. Blocks of automatics of even the smallest plants suggest the possibility of connecting the supplying pump to regulate its work. We need to get plant for office. How to choose required capacity? Plant capacity in this case should be calculated on the basis of the norms SNiP 2.04.01-85 "Domestic water supply and sanitation." How do I know that the industrial waste water are subject to BIOTAL technology treatment? You must send to the UKRBIOTAL LLC analysis of wastewater, which is supposed to be cleaned, besides sure to specify what is the production and which way of water utilization provided for the project. Are there any requirements for the compressor house floor for the monoblock units electric accommodation? We do not impose any special requirements to the floor of the compressor house, as monoblock plants compressors are located on the stilts on the wall. For plants with capacity more than 8 m3/day are used compressors with a large mass. How to provide a foundation for them? Compressors in plants up to 100 m3/day can be placed on the brackets and fasten to the wall as their vibration is minimal, and the weight does not exceed 43 kg. Plants of greater productivity should include small foundations so that the height of the foundation was not less than 20 cm. This precaution will protect compressors from getting into the water in the case of emergency flooding of the station. How to solve the problem of ventilation for the building of sewage treatment plants? The multiplicity of the exchange of air is determined by calculations of moisture removal from a premise (SNIP 2.04.03-85, p.8.12). Usually it is five-time exchange of air per hour. Do you use metal braces for the ferroconcrete part arrangement? In the ferroconcrete part for plants BIOTAL metal staples are not used. In general, during the construction of ferroconcrete part for our plants you should pay particular attention to waterproofing ensure, both external and internal. What should be the height of the ceiling in the compressor house for a monoblock plant? The height of the ceiling in the compressor house should be approximately 2.5 m for ease of maintenance. For example, on experience from plants service, we recommend placement of blocks of automatics on a strongly certain height. What should be the height of the neck of manhole for the service? The height of the neck of manhole for plant maintenance shall not be greater than 300 mm. If you want more, it must be agreed individually with UKRBIOTAL LTD. © 2006-2016 BIOTAL. All rights reserved. Wastewater treatment Autonomous sewage, grease, biological wastewater treatment systems, wastewater treatment, water purification equipment, installations of wastewater treatment, wastewater treatment plants, biological water treatment Created by - Magica Home ABOUT US BIOTAL TECHNOLOGY PRODUCTS PLANNING FAQ CONTACTS QUALITY DOWNLOAD NEWS LLC UKRBIOTAL general office, plants BIOTAL manufacturing: 33003 Ukraine, Rivne, 2А Hrushevsky str. Office-manager: tel./fax: (0362) 26-64-17, (0362) 69-06-45, (0362) 26-28-97, (0362) 45-07-25 cell: +38 (067) 362-09-03 e-mail: Marketing manager: Selection of plants, registration of contracts, advertising tel.: +38 (067) 363-35-85